Measurements with tracer gases

Ascertaining air quality and testing of the ventilation concept

Criteria for air quality
The air change rate, the ratio of external volumetric flow to indoor air volume, is the parameter commonly used for air exchange. The age of the air, describing the length of time the air has remained in the room, and the ventilation efficiency, indicating the effectiveness of the ventilation system, compose further air quality criteria for the assessment of air circulation in a room.

Measurement methods
Air exchange parameters can be determined indirectly by means of indicator gas measurements, whereby a small amount of a tracer gas is injected into the room or building volume to be examined. The air exchange parameters can then be ascertained by the decline in tracer gas concentration caused by natural as well as mechanical ventilation.

Our services

     
Syringes filled with tracer gasses
Results of an air age measurement
 

Next Courses

PHPP Expert
Passive House Designer / Consultant
Construction Verifier
Site Supervisor
read more

e-learning

Events

iPHA Webinar | "The state of Passive House in Latin America" | December 6, 2023
read more

5 - 7 April 2024 | Innsbruck, Austria
read more

Component Database

Passive House
Component Database
read more


Projects

read more

New developments

designPH
read more

NEW: PHPP 10 (2021)
read more

Seals for Certified Passive House Components
read more


Passive House Classes,
Classic, Plus, Premium
read more


EnerPHit -
PHI certification for retrofits
read more


Wall plaque
for certified Passive Houses
read more

 

Press releases

Latest press releases

Research & Literature

Passive Houses for different climate zones
more

Retrofits with Passive House components -
EnerPHit Planner Handbook
(in German)

 

Passive House Retail Stores now out
Overview of contents
(in German)



PHI Literature

© copyright Passive House Institute 2015